What was found
AFT CABIN PASSENGER RT ENTRY DOOR AT STA 987 HAS SEVERAL AREAS O OF CORROSION UNDER PANEL 242YKF. BLENDED SMOOTH AND REMOVED CORROSION AT STA986.5 RBL 39, FOUND OUT OF LIMITS, FLOORBEAM REMOVED, LOCATED, DRILLED, AND DOUBLER INSTALLED IAW SRM 53-70-51 FIG 104, SRM 51-40-02, SRM 51-40-05.