What was found
AFT CABIN PASSENGER FLOOR BEAM AT APROX AT STA 947.5 HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION AT STA 907.5 FOUN OOT THE LIMITS IAW SRM 53-70-51 ORIGINAL MATERIAL .175",MATERIAL LOSS .066. SRM 51-40-02 AND 53-70-51. SRM 51-20-01, NSTALLED FLOOR BEAM REPAIR , FABRICATE REPAIR-TRIM ,DRILLED AND DEBURRED IAWSRM 53-70-51, REPAIR FIG 206.