What was found
DOOR 1L DIFFICULT TO OPEN FOUND UPPER GUIDE ARM ATTACH PIN SECURE FASTENER SHEARED, CAPTURE WASHER MISSING, AND ATTACH PIN MIGRATED, RPL ITEMS 82, 85, 70 SCREW, WASHER, PIN REF IPC 52-11-21-01, ENSURED PROPER ENGAGEMENT OF LOWER LINK ARM, LUBED UPPER GUIDE ARM CHANNELS AND RELATED AREAS, CYCLED DOOR 10 TIMES WITH NO BINDING NOTED OR OTHER INCIDENTS.