As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND FOWARD EXIT SIGN AT DOOR 3 RIGHT INOP REMOVED CEILING PANEL ABOVE DOOR 3 RIGHT FOR TROUBLESHOOTING AND REMOVED DADO PANEL JUST AFT OF DOOR 3 RIGHT RANG OUT BOTH WIRES ON LIGHT FORWARD FOR DOOR 3 RT AND FOUND AN OPEN ON GROUND WIRE REF AWD 33-51-22, PG 905 SHEET 1. ACCOMPLISHED REPAIR PER ECRA3351-01266 AND REF SWPM 20-30-12. EM ERGENCY LIGHTS WORKING NORMALLY. CKS OK.