What was found
FUSELAGE SKIN PREVIOUS REPAIR DOUBLER SKIN FOUND SURFACE CORROSION AT STA 1197+120 BETWEEN STR 37L-38L CORROSION REMOVED PER SRM 51-10-02, ORG 0.065'' BLEND OUT AREA REMAIN 0.045'' WIDTH 2'' LENGTH 2'', CHECKED NOT WITHIN SRM53-00-01 ALLOWABLE DAMAGE 1 FIG 101 LIMITS. PREVIOUS DOUBLER REMOVED AND DISCARDED PER SRM 51-40-02. REPAIR PARTS MADE AND ISNTALLED PER SRM 53-00-01 REPAIR 14 FIG 201, WEIGH 0.75LB. ADD EMP:V897381 DIP REQUIRED PER SRM 53-00-01 REPAIR 14 FIG 201 TABLE V RII APPROVED BY HX106494 CARRY AS REQUIRED DUE TO CAT B REPAIR.