What was found
AFT WET AREA BETWEEN STA 947.5 AND STA 967, LBL 25, FOUND CORROSION ON FLOOR SUPPORT (REF NR 99845516). REMOVED CORROSION ON FLOOR SUPPORT AS PER SRM 51-10-02 FOUND OUT OF LIMITS AS PER SRM 53-70-51. REMOVED AND REPLACED FLOOR SUPPORT AT STA 947.5 - STA 967 LBL 25" AS PER SRM 51-40-02. SEE SIGNOFF FOR WORK ACCOMPLISHED.