What was found
B757-53-3-0551 (SECONDARY FINDING)MAIN CABIN FWD FLOORBEAM AT A PPROX STA 345 RBL 2-LBL 40 HAS CORROSION,16-126 REF ENGINEERING N/R 0073053 REMOVED CORROSION FROM MAIN CABIN FLOORBEAM UPP CAP STA 345 RBL 2 TO LBL 40 (L=22 X W=2 D=.028) FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 ALLOW DAMAGE 1 FIG 101 DET III AND IV, CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED PERMANENT REPAIR AT FLOORBEAM STA 345 RBL 21 TO LBL 58 IAW SRM 53-00-51. ED ON NR 0073053. THIS IS TRANSCRIBED INFORMATION ACCOMPLISHED AND RECORD COMPLETED AND ACCEPTED BY ENG.