What was found
ENTRY DOOR 4L EICAS ON CLIMBOUT. F/A REPORTED HANDLE POPPED UP AND WOULD NOT RESET. REMOVED SLIDE BUSTLE TO FOM. REMOVED UPPER LINER TO FOM. REMOVED LOWER LINER TO FOM. REMOVED DOOR CLOSE-OUT SEAL ASSY TO FOM. REMOVED DOOR HANDLE CAM PLATE COVER TO FOM. ADJUSTED LATCH CAM PLATES 4 EACH AS PER AMM 52-11-00-825-011, ADJUSTED AND CHECKED DOOR STOP PINS AS PER AMM 52-11-00-825-037 & 52-11-00-825-050 HANDLE FORCE CHECK, GOOD. ACCOMP. RII INSP. OF CAM PLATE ADJUSTMENTS, STOP PIN RIG AND DOOR HANDLE FORCE CHECKS, AS PER ABOVE NOTED AMM''S.