What was found
FWD CARGO PIT STR42L HAS CORROSION FR33-34 (A3NB-53-3-6105) REF HAECO LCQ NR 9299131 AND GEN ACCOMPLISHED REPAIR ON STR 42L AT FR 33-34 IAW SRM 53-21-13-300- 004.THIS IS A CATEGORY B REPAIR. REQUIRES INSPECTION AT 60,000 F C/120,000 FH WHICHEVER OCCURES FIRST FROM REPAIR EMBODIMENT IAW SRI 53-21-13-205-006.ALL WORK ACCOMPLISHED ON HAECO NR 9299131. APPROVED FOR DIP PER SRM 53-21-13-300-004 REQUIRES INSPECTION AT 60,000 F C/120,000 FH WHICHEVER OCCURES F IRST FROM REPAIR EMBODIMENT TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEW. QC REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.