What was found
BS 1417-1486, STR 24R DENT REPAIRED IAW ECRA 5331-02466, REF ELB LP 3408629 AND HAECO NR LP 9132054, DURING HKG 2C VISIT. ECRA 5331-02466 PART 2 REQUIRES INSPECTION ON OR BEFORE 37,500 FC AND REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 12,000 FC. IAW ECRA 5331-02466, DIP CREATED FOR HFEC INSPECTION IAW NDT PART 6, 51-00-01. INSPECT THE SKIN AT THE CRITICAL FASTENER ROW ALONG THE EDGE OF THE DOUBLER. REFER TO 767-300 SRM 53-00-01, RPR 1, FIGURE 201, DETAIL I AND II. ACCOMPLISH AN EXTERNAL DETAILED INSP OF THE RPR DBLR AND A 2-INCH WIDE ZONEAROUND THE RPR IAW SRM 53-00-01, RPR 1, FIG 201, DETAIL I AND III. APPROVED FOR DIP PER ECRA 5331-02466. PART 2 REQUIRES INSPECTION ON OR BEFORE 37,500 FC AND REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 12,000 FC THEREAFTER TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. QC REVIEWED. QC REVIEWED.