What was found
B757-53-3-0492 FWD CARGO LH FRAME AT STA. 600 AND S-24L HAS A SM ALL DENT AS MARKED. 83-035. REF ST-ENG N/R 0071496. CHECKED LIMITS TO DENT AT FWD CARGO LH FRAME STA 600, S-24L; L=. 60", W=.50", D=.010". OUT OF LIMITSIAW B757-300 SRM 53-00-07, AD 1, FIG 101 ACCOMPLISHED ECRA 5310-07682, PART 1 INTERIM REPAIR. WORK WAS ACCOMPLISHED BY MECH V920993. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE A/C REACHES 40700 TOTAL A/C FLT CYCLES.PLANNING TO CONTACT ENGINEERINGAFTER 33700 FLT CYCLES BUT BEFORE 34700 CYCLES FOR INSP REQUIREMENTS. ACCOMPLISHED ECRA 5310-07682, PART 1 INTERIM REPAIR. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE A/C REACHES 40700 TOTAL A/C FLT CYCLES.PLANNING TO CONTACT ENGINEERINGAFTER 33700 FLT CYCLES BUT BEFORE 34700 CYCLES FOR INSP REQ. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC QC REVIEW INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.