What was found
REF EA 5510-01843 REV H FOUND ON R/H HORIZ STAB LOWER SKIN AT STA 101.90 CRACK MEASURING 10" FWD AF AFT SPAR 1" IN LENGTH R/H HORIZ STAB LOWER INSPAR SKIN STA 101.90 HAS BEEN REPAIRED IAW SRM 55-10-01 REP 11 REF F/C N/R 9700272 INSP THRESHOLD AT 56''000 TOT F/C FOLLOWED BY REPEAT INSP EACH SUBSEQUENT 9,000 FLT CYC''S PER STEP 5.A. TABLE 204 TOMC APPROVED. PERFORM INITIAL INSPECTION AT 56000 CYCLES AND REPEAT INSPECTIONS EVERY 9000 CYCLES THEREAFTER. TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED. QC REVIEWED QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.