What was found
B757-53-3-6043 SECONDARY FINDING DENT ON FWD CARGO LH FRAME UPPE R FLANGE AT STA 540 ABOVE STR 24L REF. ST. ENGINEERING N/R 0076173 CHECK LIMITS TO DENT ON FWD CARGO LH FRAME AT STA 540 ABOVE S-24 L;L=.92",W=.90",D=.024".OUT OF LIMITS IAW B757-200 SRM 53-00-07 AD1,PG 101,FIG 101. REPAIRED FRAME IAW EC/RA NO 5311-02310,PART 1 INTERIM REPAIR.DIP INITIATED TO ACCOMPLISH INSPECTION REQUIREM ENTS ON OR BEFORE THE A/C REACHING 45,100 TOTAL A/C FLT CYCLES.