What was found
L MAIN TANK INDICATING 1.4 LESS THAN FUEL BURN COMPUTATION PERFORMED FQIS BITE PROCEDURE IAW FIM TASK 28-41-00. NO PRESENT FAULTS AND NO INFLIGHT FAULTS NOTED. REQUESTED TO HAVE TANKS TOPPED OFF. MEASURED FUEL USING FSM 12-11-02. FUEL QUANTITY AGREED WITH STICKING PROCEDURE. REPLACED FQIS PROCESSOR IAW AMM 28-41-81 AS A PRECAUTION. ADD EMP:101442 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1038976 SN OFF 1077 PROCESSOR, FUEL OFF 29-2841-9-0003 1077 ON 29-2841-9-0003 0464