Service difficulty report · Actuator · Boeing 777222

Difficulty date
December 20, 2019
Submitted
December 21, 2019
Operation
Air carrier
Aircraft
N780UA
Make and model
Boeing 777222
Aircraft serial
26944
Aircraft time
91,920 hours, 16,044 cycles
Engine
Pwa PW4052
Part
Actuator
Condition
Malfunctioned
Location
Case Cooling
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TURB CASE COOL HPT R EICAS STATUS RIGHT ENGINE HIGH PRESSURE TURBINE (HPT) CASE COOLING ACTUATOR I S STUCK OR REVERTED TO ITS FAIL-SAFE POSITION. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 7560662 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: ELECTRONIC ENGINE CONTR OL (R ENG, CH A) CMC MSG# 7560662 FLIGHT STATUS: A INTERMITTENCE CODE: H PH: CRUISE NARRATIVE: ACP''D TEST ON MAT, TEST SHOWED ''FAIL'' APPLIED MEL. TO PLACE ENG 2 HPT TURBINE CASE COOLING ON DEFERRAL PER MEL 7524H AND C/W MAINT PROCEDURES APPLIED MEL, WIRE CONNECTOR DM75004 HAVE BN MOVED ICW MEL75020 R TCC VLV INOPED. REPLACED TCC ACTUATOR PER AMM75-24-05 OPS AND LEAKD CHECKED GOOD MAT TEST PASSED ROTABLE PARTS CHANGE WAS INDICATED - TT # 1270614 SN OFF 0491 ACTUATOR, VALVE OFF 27-7520-9-0001 0491 ON 27-7520-9-0001 6088