What was found
RAMP REPORTED DENT FORWARD AT 2L DOOR & MEASUREMENTS APPROX 2 INCHES BY 2 INCHES WITH DEEPEST DEPTH AT 3/16 INCHES LOCATED AT APPROX BODY STA 662 & JUST ABOVE W/L 208 BEFORE STRINGER REMOVED DADO PANEL TO INSPECT INTERNALLY, NOTE STRINGER BENT & E VIDENCE OF CRACK THAT WILL REQUIRE HFEC & CLEANUP OF EXTRENAL GO UGE TO FURTHER EVALUATE PERMANENT REPAIR COMPLETED ON N/R 5423870 AND FORM 44- 0008