What was found
B737-06-3-0288 FWD FLOOR STRUCTURE WET AREA FLOOR BEAM UPPER CHORD HAS EVIDENCE OF LIGHT SURFACE CORROSION BS 344 BETWEEN LBL 17 AND 17 APROX MKD 126-35 AS PER T/C 58-53-00-1-2700 REF AAR N/R 99870636 REMOVED AND REPLACED EXISTING TRAPED FILLERS AND STRAP REPAIR AT MAIN CABIN STA 344 UPPER CHORD FROM LBL 17 AND RBL 17 REF. B737-800 SRM 53-10-51 FIG 205 REPAIR 8 ADD EMP:V898225 RII INSPECTION ACCOMPLISHED BY AAR INSP 20