Service difficulty report · Outflow Valve · Airbus A319131

Difficulty date
February 28, 2020
Submitted
February 29, 2020
Operation
Air carrier
Aircraft
N827UA
Make and model
Airbus A319131
Aircraft serial
1022
Aircraft time
66,790 hours, 28,333 cycles
Part
Outflow Valve
Part number
VFT300B00
Condition
Malfunctioned
Location
Cabin Pressure
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

VENT AVNCS SYS FAULT UPDATED MAA CODE FIX USING VENDOR MAA SCREEN CREW PERFORMED AEVC TEST FAULTING 22HQ. APPLY MEL 2126C MAC RELATED WORK ORDER 000000002377099 AND PRTR OK TO USE MEL 2126C FOR SKIN AIR OUTLET VALVE 22HQ INOP. VALVE D EACTIVATED REF AMM 21-26-00-040-002-A MAC METER INITIATED FOR WITH VENDOR ID V902127 ACCOMPLISHED AEVC TEST, TEST IS FAULTING VALVE 22HQ. OK TO USE MEL 2126C FOR SKIN AIR OUTLET VALVE 22HQ INOP. VALVE DEACTIVATED REF AMM 21-26-00-040-002-A DEFERRED DIRECTLY BY TOMC REPLACED 22HQ PER AMM 21-26-53-400-A. TESTS GOOD. A ROTABLE PARTS CHANGE WAS INDICATED - TT # 1057667 SN OFF 2765 VALVE, SKIN AIR OFF 31-2125-9-0001 2765 ON 31-2125-9-0001 2838