What was found
PERFORME ROTO INSP FND 2EA HOLE CRACK AT LH-FR68, DOOR STOP NO.1 LOWER INBOARD HOLE & LOWER OUTBOARD HOLE REF NON-ROUTINE NO.9407 207 - ORIGINATED EA 5340-01724 OP002 STEP 3.1. PERFORMED AT LH-FR68 DOOR STOP NO.1, 2EA CRACKED HOLES REPAIRED AS PER ECRA 5341-01224 AND SRM 53-41-12-300-011 REV 132 AND REQUIRE RE-INSPECTION AT OR BEFORE A/C REACHES 45358 TOTAL FC AND REPEAT THE INSPECTION AT 9000 FC INTERVAL, THEREAFT ER. FOR AREA 1 (SHOWN IN EN PAGE 16 OF THIS ECRA), AT OR BEFORE AT OR BEFORE A/C REACHES 100158 TOTAL FC. PLANNING MUST CONTACT FR68 R, FR68 L (EXCEPT AT STOP FIG NO.1). REQUIRE RE-INSPECTION ECRA) PER THIS ECRA PART 1.2).3) AND PART 2.B).C). FOR FR66 L/R INTERVAL, THEREAFTER. FOR AREA 2 (SHOWN IN EN PAGE 16 OF THIS A/C REACHES 45358 TOTAL FC AND REPEAT THE INSPECTION AT 4800 FC ENGINEERING AFT 99500 TOTAL FC BUT BEFORE 99800 TOTAL FC FOR INSPECTION INTERVAL & METHOD PER ECRA 5341-01224 PART 1 B).1) AND PART 2 A). RII BY TA620.