What was found
R/H HORIZONTAL STABILIZER LOWER IN-SPAR SKIN PANEL IS CRACKED AT STAB STA 157.1 APPROX 16" FROM AFT SPAR REPAIRED CRACKED SKIN REF SRM 55-10-01 REPAIR 11 SEE HANGER NON- ROUTINE 9740028. INITIATED DIP TO INSPECT REPAIR AT 56,000 FLIGH T CYCLES AND SUBSEQUENT 9,000 REPEAT INSPECTIONS PER SRM 55-10-0 1 REPAIR 11 PARAGRAPH 5 TABLES 204 AND 206 TOMC APPROVES DIP WITH A INSP THRESHOLD OF 56000 FLT CYCLES AND A DVI AND LFEC AT 9000 FLT CYCLES PER SRM 55-10-01 REPAIR 11 TABLE 204 TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED DIP INITIATED QC REVIEWED QC REVIEWED RECORDS UPDATE INIT: 56,000 TAFC WILL ITO TO RIR (-0622) RIR: 9000 FC ...RJS/U250018