What was found
PRESSURE DECK HAS CRACK AT STA 663.75 AND RBL 43 JUST BELOW FLOOR BOARDS. REF FLEET CYCLE NR 9746952. REPAIRED VERTICAL PRESSURE WEB REF SRM57-10-10 REPAIR 3 ALT2. IS SUED DIP TO READ{PERFORM CATEGORY B REPAIR INSPECTIONS PER SRM 5 7-10-10 REPAIR 3 PAGE 217 TABLE 205 INSPECTION THRESHOLD 56,000 FLIGHT CYCLES AND 36,000 FLIGHT CYCLES THEREAFTER. HFEC AND LFEC INSPECTIONS ARE TO BE PERFORMED PER STRUCTURE DETAIL ON TABLE 2 05 SRM 57-10-10 REOAIR 3. THE INSPECTION THRESHOLD OF 56,000 N-ROUTINE 9746952 FOR ALL WORK ACCOPLISHED. FLIGHT CYCLES STARTS AFTER REPAIR INSTALLION.}SEE FLEET CYCLE NO REPAIRED VERTICAL PRESSURE WEB REF SRM57-10-10 REPAIR 3 ALT2. PERFORM CATEGORY B REPAIR INSPECTIONS PER SRM 57-10-10 REPAIR 3 3 PAGE 217 TABLE 205 INSPECTION THRESHOLD 56,000 FLIGHT CYCLES A FTER REPAIR INSTALLATION AND AT 36,000 FLIGHT CYCLE INTERVALS TH EREAFTER REF SRM 57-10-10 RPR3 ALT2. TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. TOMC APPROVED : QC REVIEWED. TOMC APPROVED : QC REVIEWED.