What was found
WHILE PERFORMING WALKAROUND, FOUND THE RT INBOARD AFT FLAP IN THE EXTENDED POSITION. DURING INSPECTION, FOUND THE FLAP ACTUATING MECHANISM ROD DAMAGED, FLAP DRIVE ATTACH FITTING DISCONNECTED AND SHEARED OFF FASTENERS. ALSO FOUND DAMAGE INSIDE BOTTOM OF FLAP CANOE FAIRING. PERFORMED REPAIR TO THE NR 6 CANOE FAIRING IAW EC/RA 2751-01797. APPLIED PROTECTIVE FINISH IAW SRM 51-20-01. END GOING TO THE FLAP IAW AMM 27-51-14-400-801. ASSEMBLED AFT FLAP DRIVE ROD TOGETHER AND ISTALLED AND TORQUED INSTALLED DRIVE ROD FITTING ON FLAP TRACK AND INSTALLED AFT FLAP DRIVE ROD ASSY IAW AMM 27-51-13-400-801,F,(9). INSTALLED REPAIRED FLAP FAIRING IAW AMM 27-51-18.