As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
UPPER FUSELAGE FWD OF THE L1 DOOR WAS DENTED AT FRAME 15. EVALUATED DENT IAW SRM 53-00-11-283-005. DENT MEASURES 1.1"X1.1" X .020" DEEP. DENT IS IN RIVETED STIFFENED AREA AND IS CATEGORY C. DENT MUST BE REPAIRED WITHIN 200 FLIGHT CYCLES IAW PARAGRAPH 2.A.(1) AND FIGURES 001 AND 002. REPAIRED IAW SRM 53- 11-13-02A PAGE 2 OF 7, INSTALLED DOUBLER IAW SRM 53-00-11-300-043.