767 - RETURN TO A SERVICEABLE CONDITION AFTER ACTIVE STORAGE PROGRAM - EMERGENCY EXIT LIGHTS INOP ROWS 20 THRU 23 FOUND EMERGENCY BATTERY CHARGER HAS CORROSION AND POWER SUPPLY BATTERY COULD NOT RECHARGE. LOCATION IS BEHIND VENT GRILL BELOW R/H OVERWING EMERGENCY EXIT. REPLACED BATTERY CHARGER REF IPC 33-51-07. EMERGENCY POWER SUPPLY BATTERY NOT IN STOCK AT IAH. REPLACED EMERHENCY SUPPLY BATTERY BELOW R/H OVERWING EMERGENCY E XIT .OPS NORMAL REF AMM TASK 33-51-07-422-012.