What was found
CREW REPORTS CAPT'S STALL WARNING GOING OFF TOO EARLY. DFCS TEST FAULTS SMYDC-1. BITE TEST OF SMYD-1 FAULTS AOA SIGNAL ERROR 27-31004, REF FIM 27-32-00-810-809. SENSOR ON ORDER. M&E 29-3412-9-0001. REPLACED ANGLE OF ATTACK SENSOR, PER AMM 34-21-05-400-801 ROTABLE PARTS CHANGE WAS INDICATED-TT NR 1043877 SN OFF 0998 IPC REFERENCE NR 34-21-05-01 SENSOR, ANGLE O OFF 29-3412-9-0001 8988 ON 29-3412-9-0001 4359 PERFORMED TAKEOFF WARNING SYSTEM TEST, REF 31-51-00-700-803-C1. OPERATIONS CHECK GOOD.