What was found
LEFT HORIZONTAL STABILIZER LOWER SKIN CRACK DETECTED AT STAB STA 184.70 APPROX 10.5 INCH FROM THE REAR SPAR. REPAIRED AS PER SRM 55-10-01 REPAIR 11 TABLE 201 AND 203 CATEGORY B REPAIR DIP REQUIRED, AS PER TABLE 204 INSPECTION REQUIREMENTS, INSPECTION THRESHOLD OF 56,000 FC AND A DETAIL VISUAL INSPECTION AND EXTERNAL LOW FREQUENCY EDDY CURRENT AT INTERVALS OF 9,000 FC THEREAFTER. REPAIRED AS PER SRM 55-10-01 REPAIR 11 TABLE 201 AND 203 CATEGORY B REPAIR DIP REQUIRED, AS PER TABLE 204 INSPECTION REQUIREMENTS, INSPECTION THRESHOLD OF 56,000 FC AND A DETAIL.VISUAL INSPECTION AND EXTERNAL LOW FREQUENCY EDDY CURRENT AT INTERVALS OF 9,000 FC THEREAFTER TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED ALL WORK COMPLIED WITH IN FLEET CYCLE N/R 9757664 QC RECORDS UPDATE-AP QC REVIEW INIT: 56000 FC INIT WILL ITO TO RIR (-2697) RIR: 9000 FC AP U366012.