As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT AFT EMERGENCY EXIT DOOR INTERNAL STRUCTURE AFT VERTICAL INTERCOSTAL CRACKED AT FASTENER HOLE, PER NR9296358 GEN BY V052030. REMOVED AND REPLACED RT AFT EMERGENCY EXIT DOOR INTERNAL STRUCTURE AFT VERTICAL INTERCOSTAL SEGMENT, IAW SRM 51-72-11-911-001 BY MECH V929087 INSP BY N078592 PER NR9296358.