What was found
AFTER T/O WHEN WE WENT FROM FLAPS 5 TO 1 WE GOT TRAILING EDGE FLAP DISAGEE AND FLAP STAYED AT FLAP 5 ABOVE INF IS ACCURATE, PER CREW DEBRIEF. AT ARRIVAL, BITE CHECKED FSEU AND FLT LEG 0 SHOWS C FLAP/STAB POS WITH CORRELATED FAULT MESSAGE 27-51101, FDE "TE DISAGREE" INTERMITTENT. NEED TO RESEARCH AND TS AS NECESSARY. CHECK AS NECESSARY FOR TS, PER FIM 27-51-00-815-809 PG 10 TABLE A, NEED TO ACCOMP FSPM BITE. FOUND NO CURRENT FDE OR FAULTS. PERFORMED BITE ON FSEU CONFERMED MESSAGE 27-51101 ON LEG 0. RAN FLAP/SLATS UP AND DOWN SEVERAL TIMES, AMBER CAUTION "TE FLAP DISAGREE" BETWEEN DETENTS 5-15. FLAPS NEVER STOPPED AND MESSAGE WAS ONLY MOMENTARY. PERFORMED BITE CHECK ON FSEU FAULT MESSAGE 27-51104. PERFORMED FSPM, REF FIM 27-58-00-01 FIG 104, NO FAULTS. NEED MORE T/S 839 C FLAP/STAB POSITION P50) ACP''D FIM 27-51-00-815-838 WITH EICAS "TE FLAP SHUTDOWN" SHOWN. EICAS AND RELAY K350, OPERATIONS NORMAL. ORDERED M476 FLAP POS XMTR 4 M ADJUSTMENT AND TEST, PER AMM27-51-45-822-161 REPLACED NR 4 FLAP POSITION XMITER, PER AMM27-51-45. NEED TO ACP ROTABLE PARTS CHANGE WAS INDICATED-TT NR 1070931 S/N OFF 1774 IPC REFERENCE NR 27-51-45-05 TRANSMITTER, FL OFF 76-2754-9-0002 1774 ON 76-2754-9-0002 0236 ACP ADJUSRMENT OF FLAP POSITION NR 4, PER AMM 27-51-45-822-161. FSEU BITE CHECKS GOOD. OPERATION OF FLAPS NORMAL WITH NO EICAS MESSAGES OR FLAP SHUTDOWN. POSITION INDICATION CHECKS OK. SYSTEM CHECKS OK.