What was found
HYD G ENGINE 1 PUMP LO PR TOMC KROWN CHECKED GREEN HYD MODULE AND CASE DRAIN DPI, NOT POPPED. CHECKED SECURITY OF FIREWALL DISCONNECTS, TIGHT. RAN ENGINE AND GOOD PRESSURE, CYCLED GREEN PUMP AND OPERATED NORMAL. CONTINUE TO T-S 71-51-02 SHEET 1, WIRES GOOD. FIRE WALL AND ACCOMPLISHED HAND OVER HAND INSPECTION, REF AWM WRANG WIRES FROM PRESSURE SWITCH 1074GK AND PUMP G 1030GK TO CHANGED SWITCH 1705GK AS PRECAUTION, REF AWM29-11-01 PAGE 3. R & R OF NR 1 ENGINE HYDRAULIC PUMP PRESSURE SWITCH, REF AMM 29-11-17-000-101-A AND 29-11-17-400-010-A. SW RPLCD WAS FIN 1074GK.