What was found
CORROSION FOUND ON LOWER SURFACE OF LT WING AT BBL 70.85, OUTBOARD OF T-CHORD FASTNER 10-3. SPT L/P 5866413. ACCOMPLISHED ALL REWORK, IAW ECRA 5725-01069. NO FURTHER ACTION REQUIRED. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U 354653, DATE 1/27/2021 INSPECTION ACCOMPLISHED.