What was found
AD 2008-16-12 SUPPORT TASK EA 5300-01986 OP 4 RH STA 2195.75 BETWEEN 5 & 10, 1EA FASTENER FOUND CRACK AT RH STATION 2195.75 BETWEEN STR 7 & 8. ACCOMPLISH REPAIR PER OP 004 STEP 6.0. REF NR LP 9130150. FUSELAGE RH STA 2195.75 BETWEEN STR 7 AND STR 8 CRACKED SKIN CUT AND REMOVED AS PER EA 5300-01986 REV A OP 004 STEP 6.0, HFEC INSPECTION CARRIED OUT AS PER B777 NTM PART 6, 51-00-01 PROC 2 AND 51-00-02 PROC 3, 51-00-07, REV 78, MAR 01/2020, RESULT: CRACK FREE, EA 5300-01986 REV A OP 010 ACCOMPLISHED. ADD EMP:V896888 RII INSPECTION DONE BY HX146606.