As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FROM TEST FLIGHT - TEST FLT AT 7.5 AP. THE TOP STRIKER LATCH WOU LD NOT REST. GENERATED ON HAECO LCQ N/R 9296979 (38979) BY MECH V892443. ACCOMPLISHED ADJUSTMENT OF FLT DOOR STRIKER LATCH IAW A319 AMM 5 2-51-00-820-051-A. ADJUSTED CHECK GOOD. PERFORMED BY MECH V06175 7 AND INSPECTED BY V923683. PRESSURIZED ACFT TO 7.6PSI IAW AMM 05-53-00-780-002-001, CHECKED LATCH AND NO DEFECTS NOTED. DOOR OPERATES NORMALLY.