As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH FR-16 STOP #7 UPPER AND INBD LOWER HOLE HAS A CRACK INDICATIO N AT 1 O''CLOCK IN THE INTERCOSTAL GEN BY V061632 PER NR9292398 / 38398. REMOVED AND REPLACED RH FR16 STOP 7 INTERCOSTAL FITTING IAW A319 SRM 51-42-11-00 AND ECRA 5311-02542 DWG R531113118 BY MECH V061 680 INSP BY V061682.