What was found
CORROSION FOUND AT LAV VENT HOLE DOUBLER REPAIR AT FR68-70 & STR 30RH-34RH REF LP 3570424 AND ECRA 5341-01071 USED FOR INITIAL RE PAIR. REMOVED EXISTING REPAIR, INSTALLED NEW DOUBLER RPR IAW NEW ECRA 5330-06822. DIP CREATED IAW ECRA 5330-06822 REQUIREMENTS ACCOMPLISH INSPECTI ON REQUIREMENTS IAW PART 2 OF ECRA 5330-06822 ON OR BEFORE THE ACFT REACHING 62269 TTL FLT CYC. CURRENT ACFT CYCLES 32346 REPAIR ACCOMPLISHED BY BQN TECH 5H0883 & 5H0318 AND INSPECTED BY 5H0619. NOTE: PLANNING TO CONTACT ENGINEERING AFTER 57000 TTL ACFT CYCLES BUT BEFORE 58000 TTL FLT CYCLES FOR ECRA 5330-06822 PART 2 INSPECTION REQUIREMENTS. DIP CREATED IAW ECRA 5330-06822 REQUIREMENTS ACCOMPLISH INSPECTI ON REQUIREMENTS IAW PART 2 OF ECRA 5330-06822 ON OR BEFORE THE ACFT REACHING 62269 TTL FLT CYC. CURRENT ACFT CYCLES 32346. OPBLM CHRISTIANSEN TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEWED RECORDS UPDATE..KJB QC REVIEWED INIT:>57000<58000 TAFC (PLN TO CONTACT ENG) T/A: 62269 TAFC..KJB U372999