What was found
REF HAECO LOG PAGE 9439516 AFT CARGO COMPARTMENT BILGE AREA FR60 -61 STGR 32L FOUND CORROSION. REF HAECO LOG PAGE 9439516 AFT CARG COMPARTMENT BILGE FR60-61 ST GR 32L CORRODED. STRINGER REPIRED AS PER SRM 53-00-13-300-001 RE V 135. THIS REPAIR APPROVED AS CATAGORY B REPAIR. REQUIRED REPEAT INSPECTION THRESHOLD FROM REPAIR EMBODIMENT 60000 FC/1200 00FH SUBSEQUENT INSPECTION AT INTERVALS TBD. INSPECTION METHOD T BD AS PER SRI 53-00-13-205-001 REV 135. OKAY TO DIP INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT IS 60000 FC OR 120000 FH WHICHEVER COMES FIRST WITH SUBSEQUENT INSPECTIONS TBD REF SRI 53-00-13-205-001 TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. REVIEWED QC REVIEWED