P61 SQUIB TEST FOUND LH & RH SPOILER AND SLIDE LIGHT INOP, REF NRC 9130152 TROUBLESHOOTING CARRIED OUT FOUND R/H AND L/H POWER SUPPLY BATTERIES WAS POWER LOW,R/H AND L/H OFF WING SLIDE POWER SUPPLY ASSY AND BATTERIES REPLACED AND SQUIB TEST TEST CARRIED OUT RESU LT NORMAL AS PER FIM TASK 25-65 FAULT TREE818,TASK25-65,FAULT TREE 820,AMM 25-65-17 AND AMM 26-65-00. ADD EMP:V919559 FORM 44-0008 ITEM 1 TO 4 ACCOMPLISHED