What was found
DURING WALKAROUND FOUND METAL SHAPED CLIP EMBEDDED INTO LOWER SURFACE OF INBOARD FWD FLAP ON RT WING. DAMAGE DIMENSION IS A HOLE 1.2" X.4" WIDED. LOCATION IS AT BS 321 WITHIN ZONE 7 IAW SRM 57-53-01 FIGURE 105. REPAIR PUNCTURE IAW SRM 57-53-01 ALLOWABLE DAMAGE 1 FIGURE 107 ITEM 2. APPLIED SPEED TAPE. REPAIR THE DAMAGE AT 4000 FLIGHT CYCLE OR 2 YEARS PER SRM 57-53-01 FIGURE 107 SHEET 1 OF 4. REINSPECTED SPEED TAPE ON RH WING INBD FWD FLAP , SPEED TAPE IS SECURED AND IN SATISFACTORY CONDITION, NO FURTHER DEFECT NOTED AT THIS TIME. OK TO CONTINUE. RHW T/E I/B MAIN FLAP LOWER SURFACE SKIN PANEL PERFORMED REPAIR AS PER ECRA 5753-01929 REV- AND RI 57-00-14615 REV A REFER FORM 44-0008 ITEM 1 TO 31 ACCOMPLISHED ADD EMP:V896876 RII BY HX329567,APPROVED REOPEN HKG U220332 16JUN21 FOR: INSUFFICIENT INFO PROVIDED TOMC RE-OPENING DIP DUE TO DIP CLEARED WITH DIFFERENT SOURCE DOCUMENT THAN ORIGINALLY USED TO PLACE DIP. RT WNG I/B FWD FLAP LOWER SURFACE I/B FWD METAL SHAPED CLIP EMBEDDE D AREA REPAIRED IAW SRM 51-70-04 REPAIR 4(E