Service difficulty report · Fire Loop · Boeing 737824

Difficulty date
June 18, 2021
Submitted
June 18, 2021
Operation
Air carrier
Aircraft
N76288
Make and model
Boeing 737824
Aircraft serial
33451
Aircraft time
53,680 hours, 18,945 cycles
Part
Fire Loop
Part number
90201801
Condition
Faulted
Location
Rt Engine
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

#2 ENGINE OVERHEAT LIGHT ILLUMINATED ON TAKE OFF ROLL WITH #2 ENGINE OVERHEAT DET SELECTED TO B. REF MEL 2602B. ( A LOOP FAULT AND DE SELECTED) #2 ENGINE B LOOP ALSO INDICATING INTERMITTENT FAILURE. DUAL LOOP FAULT. REF LOG # 6492409. REPLACED #2 ENG LEFT CORE FIRE DETECTION ASSY REF AMM 26-11-01/401. FIRE DETECTION TEST OK. ADD EMP:010801 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1013785 SN OFF 3380 DETECTOR, FIRE, OFF 29-2611-9-0003 3380 ON 29-2611-9-0003 2138 DETECTOR, FIRE, OFF 29-2611-9-0004 1845 ON 29-2611-9-0004 5153 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1990948 SN OFF 1845 REPLACED LOOP B UPPER FIRE DETECTOR. REPLACED LOOP A #2 ENG. LOWER FIRE DETECTOR. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1169444 SN OFF 3569 DETECTOR, FIRE, OFF 29-2611-9-0002 3569 ON 29-2611-9-0002 6909 DETECTOR, FIRE, OFF 29-2611-9-0001 3417 ON 29-2611-9-0001 8803 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1170443 SN OFF 3417 REPLACED LOOP A #2 ENG. UPPER FIRE DETECTOR. REPLACED FIRE/OVERHEAT CONTROL PANEL. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1168740 SN OFF 0612 PANEL, CONTROL, OFF 29-2615-9-0001 0612 ON 29-2615-9-0001 2063 REPLACED ALL #2 ENG. FIRE DET. LOOPS. DETECTION SYSTEM CHECKS GOOD. NO FAULTS FOUND AT DETECTION CONTROL PANEL WHICH WAS ALSO REPLACED.