What was found
(A3NB-53-3-6186) CORROSION ON AFT CABIN FLOOR BEAM Y765 BETWEEN FR68 AND FR70 (74-07) REMOVED CORROSION ON AFT CABIN FLOOR BEAM Y765 IAW SRM 51-74-00 L=2.15" W=2.8" D=0.045 FOUND TO BE LIMITS IAW SRM 53-00-14 FIG 0 1, REMOVED AND REPLACED IAW 51-72-11-911-00, ORIGINAL THICKNESS =0.160 REMOVED MATERIAL=0.045", REMAINING THICKNESS =0.115".