As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(A3NB-53-3-6185)-Y1292 FLOOR BEAM FR66-68 HAS MULTIPLE CORROSION SPOTS. (REMOVE DAMAGE, CHECK LIMITS) REPLACED FLOOR SUPPORTS P/N:D5347220924500 AND P/N:D534721722050 0 BETWEEN FR64-FR68 AND -Y1292 IAW SRM 51-72-11. ATTACHED FORM 4 4-0008 EMP# V934611 WORK ACCOMPLISHED AT ST ENGINEERING MOBILE A T BFM ON NR#0013784