What was found
RIGHT ENGINE DRIVE LIGHT ILLUMINATED AND CREW DISCONNECTED IDG. FOUND #2 ENG IDG LOW OIL QUANTITY MESSAGE ON EICAS STATUS PAGE. FOUND IDG OIL LEAKAGE FROM BOTH QUICK DISCONNECTS SERVICE FITTINGS FOR OVERFLOW DRAIN AND PRESSURE FILL. REPLACED QUICK DISCONNECT FITTINGS REF AMM 24-11-01-726-001. RECONNECTED IDG DRIVE, SERVICED IDG REF AMM 12-13-03. PERFORMED IDLE RUN FOR 15 ADD EMP:126318 DEFECTS AND VERIFIED NO OIL LEAKS FOR GENERATOR DRIVE. MINUTES AT 77% ELECTRICAL LOAD ON #2 ENGINE GENERATOR WITH NO