What was found
FUSELAGE SKIN 4 EACH CRACKS FOUND AT STA1630-1654 STR 14AR WHILE PERFORMING INSPECTION BY EA 5380-01178 OPS 004. INSTALLED DOUBLER REPAIR STA 1630-1654 STR 14AR IAW SRM 53-80-01-2R-7 REPAIR 7 FIG 201. REPAIR IS PERMANENT CAT B. INSPECTION THRESHOLD IS 30,000 FLT CYCLES AFTER ACFT DELIVERY OR WITHIN 7500 FLT CYCLES FROM THE REPAIR INSTALLATION, WHICHEVER COMES LAST. REF SRM 53-80-01-2R-7 REPAIR 7 INSPECTION REQRMNTS PARAGRAPH 5 TABLE 202.