What was found
AFT CARGO COMPT BILGE AREA EXISTING STRINGER REPAIR AT FRAME 58- 59 STR 43LH HAS CORROSION. PER HAECO LCQ NR 9296565/30565 GENERA TED BY V061595 REPAIRED AFT CARGO STRINGER SPLICE AT FR 58-59 STR 43L/H IAW 320 CORRECTING DIP LIMITS TO THE FOLLOWING 60,000FC / 120000FH REF A SRM 53-00-13-300-001. INSPECTION THRESHOLD FROM TIM EOF ADL/REP RI 53-00-13-205-0001 TABLE 6 AIR EMBODIMENT 60,000 FC / 12,000 FH REF SRI 53-00-13-205-001 OK TO CARRY PER SRI 53-00-13-205-001, REQUIRES INSPECTION AT TOMC-APPROVAL FROM SC1ELBYC COMMENT 60000 F/C''S OR 120000 F/H''S FROM REPAIR EMBODIMENT. DIP 53-DIP . QC REVIEW RECORDS UPDATE......SS QC REVIEWED T/A : 60000 F/C OR 120000 F/H....SS