What was found
REFERENCE 6984384 DURING EXTERNAL REPAIR SURVEY AT HMV3 IN BQN, FOUND DOUBLER AT FRM 2 STR 43-44L, DURING EVALUATION A REPAIR RECORD WAS UNABLE TO BE LOCATED. AS SUCH REPAIR AND EVALUATION MUST BE PERFORMED. REPLACEMENT OF DOUBLER PERFORMED IAW SRM TASK 53-11-11-300-041 ADD EMP:V072465, V933558 SRI 53-11-11-205-037. PICTURES ADDED REMOVAL OF EXISTING DOUBLER PERFORMED IAW SRM 51-42-11 PARA. 2E. PER SRI 53-11-11-205-037, TABLE 001, INSPECTION THRESHOLD FROM AREA OF SKIN THICKNESS BETWEEN 1.2MM (.047IN) AND 2.2MM TIME OF ADL/REPAIR EMBODIMENT, 60,000 FC OR 120,000 FH, (.087IN). NEW DOUBLER FABRICATED AND INSTALLED IAW SRM LIMITATION GIVEN BY WHICHEVER VALUE FC/FH OCCURS FIRST. REPAIR 53-11-11-300-041 PRINCIPLE 2. REPAIR IS CLASSIFIED AS A IS LOCATED IN ZONE 1. CATEGORY B REPAIR AND REQUIRES REPETITIVE INSPECTIONS PER SRM ADD EMP:V072465, V933558