What was found
AFT CARGO COMPT FLOOR BILDGE STR39 RH FR61 HAS CORROSION EVIDENCE. DOT 61-052 0003827275 AND COUPLING A53986217 BATCH 0003853799 IAW SRM SHEETS 02 AND 05. WORK ACCOMPLISHED ON VT MAE N/R 0015734 BY OF ADL/REPAIR EMBODIMENT FC 60000 / FH 120000 WHICHEVER ACHIEVED 53-41-13-04-D AND SRM 53-00-13-300-001 FIG 001 SHEET 5 VT MAE MOBILE EMP V934344. THIS REPAIR REQUIRES REPETITIVE INSP FIRST SUBSEQUENT INSPECTIONS TBD. INSTALLED STRINGER REPAIR IAW SRM 53-00-13-300-001 FIG 001 IAW SRI 53-00-13-205-001 TABLE 6 INSPECTION THRESHOLD FROM TIME DAMAGE OUT OF LIMITS IAW SRM 53-41-13-283-002 FIG 001 SHT 01. CUT OUT DAMAGE IAW SRM 51-42-11/001 AND NDT''D CUT OUT IAW NTM 51-10-08. FABRICATED REPAIR PARTS: STRINGER DAN50B09 BATCH APPROVED FOR CARRY PER SRM 53-00-13-300-001, FIGURE 1, SHEET 2. TOMC-APPROVAL FROM SC1ELBYC COMMENT REQUIRES INSPECTION PER SRI 53-00-13-205-001 FROM REPAIR EMBODIMENT AT 60000FC/120000FH TBD IN CASE OF LIFE EXTENSION BEYOND 60000FC/120000FH. QC REVIEWED QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.