What was found
AFT CARGO COMP: FLOOR BILDGE STR42 LH FR55 HAS CORROSION EVIDENCE. DOT 61-046 BATCH 000382727 AND COUPLING A53986217 BATCH 0003853799 IAW SRM 04, 05 & 06. WORK ACCOMPLISHED ON VT MAE N/R 0015728 BY VT MAE /REPAIR EMBODIMENT FC 60000 / FH 120000 WHICHEVER ACHIEVED FIRST 53-41-13-07-A AND SRM 53-00-13-300-001 FIG 001 SHEET 5. INSTALLE MOBILE EMPLOYEE V934344. THIS REPAIR REQUIRES REPETITIVE INSP SUBSEQUENT INSPECTIONS TBD. D STRINGER REPAIR IAW SRM 53-00-13-300-001 FIG 001 SHEETS 02,03 IAW SRI 53-00-13-205-001 TABLE 6 INSP THRESHOLD FROM TIME OF ADL DAMAGE OUT OF LIMITS IAW SRM 53-41-13-283-002 FIG 001 SHT 01. UPDATE: REPAIR ACCOMPLISHED IAW SRM 53-00-13-300-001 FIG CUT OUT DAMAGE IAW SRM 51-42-11/001 AND NDT''D CUT OUT IAW SRM 001 SHEETS 02 AND 05. NTM 51-10-001. FABRICATED REPAIR PARTS: STRINGER DAN50B09 APPROVED FOR CARRY PER SRM 53-00-13-300-001, FIGURE 1, SHEET 2. TOMC-APPROVAL FROM SC1ELBYC COMMENT REQUIRES INSPECTION PER SRI 53-00-13-205-001 FROM REPAIR EMBODIMENT AT 60000FC/120000FH TBD IN CASE OF LIFE EXTENSION BEYOND 60000FC/120000FH. DIP 53-DIP REPAIRS 2, 3,4,5,6 ARE ALL DIFFERENT REPAIRS, WHICH SPECIFIC REPAIR WAS ACP''D? UPDATE: REPAIR ACCOMPLISHED IAW SRM 53-00-13-300-001 FIG QC REVIEWED 001 SHEETS 02 AND 05. QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.