What was found
AFT VARGO COMPT BILGE AREA EXISTING STRINGER REPAIR AT FRAME 55- 56 STR 43LH HAS CORRISION. TABLE 008. REPAIRED AFT CARGO STRINGER SPLICE AT FRAME 55-56 STR 43 LH IAW A320 SRM 53-00-13-300-001. INSPECTION THERSHOLD FROM TIME OF ADL /REPAIR EMBODIMENT 60,000FC/120,000FH SRI 53-00-13-205-001 OK TO DIP STRINGER REPAIR AT FR 55-56 STR 43LH PER SRM TOMC-APPROVAL FROM SC1ELBYC COMMENT 53-00-13-300-001. REF SRI 53-00-13-205-001 TABLE 8, MUST ACCOMPLISH 1ST INSPECTION AT 60000 FLIGHT CYCLES-120000 FLIGHT HOURS (WHICHEVER OCCURS 1ST) FROM REPAIR EMBODIMENT. AT TIME OF FIRST INSPECTION, REVIEW SRI AND APPLY APPLICABLE RECHECK LIMITS. Q/C REVIEWED. Q/C REVIEWED. T/A: 60K FC / 120K FH.......DB/U359554 RECORDS UPDATE