As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*EMERGENCY DECLARED* STAB OUT OF TRIM LIGHT IS ON STAB OUT OF TRIM LIGHT ILLUMINATED AT FL380 QRH COMPLIED WITH..E LECT TRIM INOP LOCK FOR REPAIR UNLOCKING REPLACED STAB TRIM ACT ON LP 7532727. ACCOMPLISHED COLUMN CUTOUT SWITCHES TEST PER AMM 27-41-00-710-801 AS REQUESTED AND TEST PASSED. PERFORMED CAT 3 TEST AND ALL TESTS PASSED AIRCRAFT IS FULL CAPABLE REF AMM 22-11-00-700-801