What was found
SUPPORT TASK- UAL QC PICK UP SHEET- DURING THE AAI RECORD REVIEW , NO RECORD OF REPAIR AND NO RECORD TO ACCOUNT FOR THE REINSPECTION OF THE FUSELAGE DOUBLER REPAIR AT FUSELAGE STATION 654+121 STR.39L AND STR.39R TRANSFER REF NON-ROUTINE LP9132196 AND ORIGINATED BY EMP V913166 2 ON OR BEFORE THE ACFT REACHES 37500 TOTAL FC. REPEAT THE INSP AT INTERVALS NOT TO EXCEED 9000 FC THEREAFTER. HAECO LOG 9132196, V897461, QC HX169517 FUSELAGE STA 654+121 - STA 676 BETWEEN S38L - S38R, SKIN REPAIRED AS PER ECRA 5330-06889 REV ORG PT1., DIP REQUIRED TO ACCOMPLISH INITIAL INSP PER THE LATEST REV OF EC 5330-06889 PT ADD EMP:V913166 HAECO LOG 9132196, V897461, QC HX169517 DIP REQUIRED TO ACCOMPLISH INITIAL INSP PER THE LATEST REV OF EC 5330-06889 PT2 ON OR BEFORE THE ACFT REACHES 37500 TOTAL FC. REPEAT THE INSP AT INTERVALS NOT TO EXCEED 9000 FC THEREAFTER. ADD EMP:V913166 DIP 53-DIP REJECTING TO UPDATE ITEM. UPDATING LOG - MAJOR REPAIR NOW SELECTED.