As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK FOUND IN THE RH FR20 #1 DOOR STOP FITTING FASTENER HOLE #3 . CRACK IS IN THE INTERCOSTAL ONLY. REMOVED AND REPLACED R/H FR20 #1 DOOR STOP INTERCOASTAL IAW SRM 51-42-11. R5311 3118 FORM 44-0008 ATTACHED EMP# V935774 WORK AC COMPLISHED AT ST ENGINEERING AEROSPACE OF MOBILE AT BFM ON NR# 0 018720.